A comparison of first-responder automated external defibrillator (AED) application rates and characteristics of AED training. Prehosp Emerg Care 2003;7(4):453-7

Date

10/29/2003

Pubmed ID

14582097

DOI

10.1080/31270300217x

Scopus ID

2-s2.0-0142094545 (requires institutional sign-in at Scopus site)   7 Citations

Abstract

OBJECTIVE: To determine whether there were associations between the characteristics of first-responder automated external defibrillator (AED) training and AED application rates.

METHODS: This multicenter retrospective cohort study analyzed data from ten emergency medical services systems where first responders were trained and equipped with AEDs. Data were provided for all out-of-hospital cardiac arrests (OHCAs) occurring over two years, including whether the first-responder AED was applied (pads attached to patient). Systems were surveyed to determine the characteristics of their initial and continuing AED training. Data were analyzed using odds ratios (ORs) with 95% confidence intervals (95% CIs).

RESULTS: Overall, the first-responder AED was applied to 53% of 2,181 OHCAs. First responders applied AEDs to 60% of OHCAs when a national AED training curriculum was used and to 49% of OHCAs when a locally created curriculum was used (OR=1.58; 95% CI=1.32-1.88). First responders applied AEDs to 61% of OHCAs when they were trained to the level of Certified First Responder or higher and to 28% of OHCAs when they were trained only in cardiopulmonary resuscitation (OR=3.97; 95% CI=3.20-4.93). First responders applied AEDs to 66% of OHCAs when they each had an opportunity to apply the AED during continuing training and to 17% of OHCAs when they did not have this opportunity (OR=9.04; 95% CI=7.15-11.42). First responders applied AEDs to 59% of OHCAs when they had not received continuing training within one year of their initial training and to 42% of OHCAs when they had received continuing training in the first year (OR=2.00; 95% CI=1.67-2.40).

CONCLUSION: Use of a national AED training curriculum, training to the level of Certified First Responder or higher, and the ability for each first responder to apply the AED during continuing training were associated with higher AED application rates. Continuing training within the first year did not appear to be as important as actually using the AED during the training.

Author List

Lerner EB, Billittier AJ 4th, Shah MN, Newman MM, Groh WJ



MESH terms used to index this publication - Major topics in bold

Advanced Cardiac Life Support
Automation
Certification
Cohort Studies
Confidence Intervals
Education, Continuing
Electric Countershock
Emergency Medical Services
Female
First Aid
Follow-Up Studies
Heart Arrest
Humans
Male
Odds Ratio
Probability
Professional Competence
Retrospective Studies
Risk Assessment
Survival Analysis
Time Factors
Treatment Outcome