Determinants of successful balloon valvotomy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum. J Am Coll Cardiol 1995 Feb;25(2):460-5
Date
02/01/1995Pubmed ID
7829801DOI
10.1016/0735-1097(94)00405-fScopus ID
2-s2.0-0028836418 (requires institutional sign-in at Scopus site) 85 CitationsAbstract
OBJECTIVES: This study reviewed our experience with percutaneous balloon valvotomy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum and defined the anatomic and hemodynamic characteristics of infants in whom this procedure is successful and provides definitive therapy.
BACKGROUND: Unlike children with valvular pulmonary stenosis, the follow-up of infants with critical pulmonary stenosis undergoing percutaneous balloon valvotomy is limited.
METHODS: Between December 1987 and August 1992, percutaneous balloon valvotomy was attempted in 12 infants with critical pulmonary stenosis (n = 10) or pulmonary atresia with intact ventricular septum (n = 2). Two outcome groups were identified: Group A patients are acyanotic, have mild residual pulmonary stenosis and have not required operation; Group B patients have required operation.
RESULTS: Of the 12 infants, 11 had a successful balloon valvotomy procedure. Group A patients (n = 7) have a residual gradient of 22 +/- 18.7 mm Hg (mean +/- SD) at follow-up of 3.2 years (range 1.2 to 5.0). In Group B (n = 5), operation was required for inability to cross the pulmonary valve (n = 1) or persistent severe hypoxemia for > or = 2 weeks after valvotomy (n = 4). Significant differences (p < or = 0.01) between the two groups (Group A vs. Group B) were identified in pulmonary valve annulus (Z value) 8.1 mm (-1.1) versus 5.5 mm (-3.4); tricuspid valve annulus (Z value) 14.0 mm (0.8) versus 8.8 mm (-1.8); right ventricular volume 65 versus 29 ml/m2; and Lewis index 10.9 versus 8.9.
CONCLUSIONS: Percutaneous balloon valvotomy is effective and likely to provide definitive therapy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum who have a tricuspid valve annulus > 11 mm, pulmonary valve annulus > or = 7 mm and right ventricular volume > 30 ml/m2.
Author List
Fedderly RT, Lloyd TR, Mendelsohn AM, Beekman RHAuthor
Raymond T. Fedderly MD Associate Professor in the Pediatrics department at Medical College of WisconsinMESH terms used to index this publication - Major topics in bold
CatheterizationFollow-Up Studies
Heart Septum
Heart Ventricles
Hemodynamics
Humans
Infant
Infant, Newborn
Pulmonary Atresia
Pulmonary Valve Stenosis
Time Factors
Treatment Outcome