Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. Am J Physiol Heart Circ Physiol 2005 May;288(5):H2465-75
Date
01/18/2005Pubmed ID
15653759DOI
10.1152/ajpheart.01107.2004Scopus ID
2-s2.0-18044371469 (requires institutional sign-in at Scopus site) 152 CitationsAbstract
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.
Author List
LaDisa JF Jr, Olson LE, Molthen RC, Hettrick DA, Pratt PF, Hardel MD, Kersten JR, Warltier DC, Pagel PSAuthors
John F. LaDisa PhD Professor in the Pediatrics department at Medical College of WisconsinPaul S. Pagel MD, PhD Professor in the Anesthesiology department at Medical College of Wisconsin
MESH terms used to index this publication - Major topics in bold
AnimalsCorrosion Casting
Hyperplasia
Iliac Artery
Male
Models, Cardiovascular
Predictive Value of Tests
Rabbits
Regional Blood Flow
Stents
Stress, Mechanical
Tomography, X-Ray Computed
Tunica Intima