Diagnostic Performance of 4D CT and Sestamibi SPECT/CT in Localizing Parathyroid Adenomas in Primary Hyperparathyroidism. Radiology 2019 May;291(2):469-476
Date
03/06/2019Pubmed ID
30835187Pubmed Central ID
PMC7440755DOI
10.1148/radiol.2019182122Scopus ID
2-s2.0-85065025739 (requires institutional sign-in at Scopus site) 124 CitationsAbstract
Background There currently is no consensus on the optimal localization procedure and imaging protocol for parathyroid adenoma. Parathyroid four-dimensional (4D) CT has emerged as a promising method for preoperative localization. Purpose To evaluate the diagnostic performance of parathyroid 4D CT and technetium 99m-sestamibi (hereafter, referred to as sestamibi) SPECT/CT in preoperative localization in patients with primary hyperparathyroidism. Materials and Methods This was a single-institution retrospective study of patients with primary hyperparathyroidism who underwent a combined imaging protocol of sestamibi SPECT/CT and 4D CT (noncontrast, contrast agent-enhanced, arterial, and delayed venous phases) acquired in a single setting from February 2013 to May 2016, with subsequent parathyroidectomy within 6 months. Reference standard for correct localization was on the basis of location denoted on operative reports, with pathologic confirmation of parathyroid adenoma or hyperplasia. By using a four-quadrant analysis, sensitivity, specificity, and area under the curve (AUC) for localization of the hyperfunctioning parathyroid gland or glands at sestamibi SPECT/CT and 4D CT were compared, per modality and in combination. Results Four hundred patients (319 women, 81 men; mean age, 61 years ± 14 [standard deviation]) were evaluated. Similar diagnostic performance was found in both combined 4D CT with sestamibi SPECT/CT and 4D CT alone (area under the curve [AUC], 0.88 [95% CI: 0.86, 0.90] and 0.87 [95% CI: 0.85, 0.90], respectively; P = .82). Both modalities outperformed sestamibi SPECT/CT (AUC, 0.78; 95% CI: 0.76, 0.81; P < .001). Four-dimensional CT showed higher sensitivity than did sestamibi SPECT/CT (sensitivity, 79.3% [414 of 522] vs 58.0% [303 of 522], respectively; P < .001). In a subset analysis, 4D CT had higher sensitivity than sestamibi SPECT/CT in patients with single-gland disease (sensitivity, 92.5% [297 of 321] vs 75.1% [241 of 321], respectively; P < .001) and with multigland disease (sensitivity, 58.2% [117 of 201] vs 30.8% [62 of 201], respectively; P < .001). Conclusion Four-dimensional CT provided superior preoperative localization compared with sestamibi SPECT/CT in patients with single and multigland disease. The combination of the two modalities did not improve diagnostic performance compared with four-dimensional CT alone. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Sinha and Oates in this issue.
Author List
Yeh R, Tay YD, Tabacco G, Dercle L, Kuo JH, Bandeira L, McManus C, Leung DK, Lee JA, Bilezikian JPAuthor
Catherine McManus MD, MS Associate Professor in the Surgery department at Medical College of WisconsinMESH terms used to index this publication - Major topics in bold
AdenomaAdult
Aged
Aged, 80 and over
Area Under Curve
Female
Four-Dimensional Computed Tomography
Humans
Hyperparathyroidism, Primary
Image Interpretation, Computer-Assisted
Male
Middle Aged
Parathyroid Glands
Parathyroid Neoplasms
Retrospective Studies
Tomography, Emission-Computed, Single-Photon
Young Adult









