Medical College of Wisconsin
CTSIResearch InformaticsREDCap

Comparison of image quality of subtracted and nonsubtracted breath hold VIBE and free breathing GRASP in the evaluation of renal masses. Clin Imaging 2021 Jun;74:15-18

Date

01/10/2021

Pubmed ID

33421698

Pubmed Central ID

PMC8193457

DOI

10.1016/j.clinimag.2020.12.027

Scopus ID

2-s2.0-85098990163 (requires institutional sign-in at Scopus site)   4 Citations

Abstract

OBJECTIVE: To compare the image quality of subtracted and nonsubtracted images obtained using volumetric interpolated breath-hold exam (VIBE) and free breathing T1 weighted Golden-angle Radial Sparse Parallel (GRASP).

METHODS: We retrospectively evaluated 27 consecutive patients who underwent MRI for the evaluation of renal masses. Contrast enhanced VIBE and free breathing GRASP imaging were performed, and subtraction images generated. Two radiologists performed quantitative and qualitative evaluations of image quality of nonsubtracted and subtracted data sets. Statistical analysis was performed using the Wilcoxon signed-rank test, paired t-test and kappa statistics.

RESULTS: VIBE images scored statistically higher for the following parameters in the coronal and axial plane: sharpness, streak artifact, image noise, and overall image quality for standard and subtracted images (all P values P < 0.001). GRASP images had significantly less subtraction artifact in the coronal (P = 0.042) plane with a similar trend in the axial plane (P = 0.079). Interreader Kappa values for qualitative images scores were fair to good (0.23-0.71). Quantitative subtracted GRASP images had significant less subtraction artifact compared to VIBE in the anterior-posterior (3.9 mm SD 2.6 mm versus 5.8 mm SD 3.6 mm, P = 0.010), and craniocaudal direction (4.4 mm SD 2.9 mm versus 7.0 mm SD 5.3 mm, P = 0.010); a trend was seen in the left-right direction (2.6 mm SD 1.4 mm versus 4.0 mm SD 3.9 mm, P = 0.084).

CONCLUSION: VIBE images have significantly better image quality than free breathing GRASP images, however free breathing GRASP images have significantly less subtraction artifact.

Author List

Huber S, Balcacer De la Cruz P, Mahan M, Spektor M, Lo R, Block KT, Israel G

Author

Ryan Lo MD Interim Chief, Assistant Professor in the Radiology department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Artifacts
Breath Holding
Contrast Media
Humans
Image Enhancement
Imaging, Three-Dimensional
Magnetic Resonance Imaging
Retrospective Studies