Medical College of Wisconsin
CTSIResearch InformaticsREDCap

Development of Prostate Bed Delineation Consensus Guidelines for Magnetic Resonance Image-Guided Radiotherapy and Assessment of Its Effect on Interobserver Variability. Int J Radiat Oncol Biol Phys 2024 Feb 01;118(2):378-389

Date

08/27/2023

Pubmed ID

37633499

DOI

10.1016/j.ijrobp.2023.08.051

Scopus ID

2-s2.0-85181813907 (requires institutional sign-in at Scopus site)   6 Citations

Abstract

PURPOSE: The use of magnetic resonance imaging (MRI) in radiotherapy planning is becoming more widespread, particularly with the emergence of MRI-guided radiotherapy systems. Existing guidelines for defining the prostate bed clinical target volume (CTV) show considerable heterogeneity. This study aimed to establish baseline interobserver variability (IOV) for prostate bed CTV contouring on MRI, develop international consensus guidelines, and evaluate its effect on IOV.

METHODS AND MATERIALS: Participants delineated the CTV on 3 MRI scans, obtained from the Elekta Unity MR-Linac, as per their normal practice. Radiation oncologist contours were visually examined for discrepancies, and interobserver comparisons were evaluated against simultaneous truth and performance level estimation (STAPLE) contours using overlap metrics (Dice similarity coefficient and Cohen's kappa), distance metrics (mean distance to agreement and Hausdorff distance), and volume measurements. A literature review of postradical prostatectomy local recurrence patterns was performed and presented alongside IOV results to the participants. Consensus guidelines were collectively constructed, and IOV assessment was repeated using these guidelines.

RESULTS: Sixteen radiation oncologists' contours were included in the final analysis. Visual evaluation demonstrated significant differences in the superior, inferior, and anterior borders. Baseline IOV assessment indicated moderate agreement for the overlap metrics while volume and distance metrics demonstrated greater variability. Consensus for optimal prostate bed CTV boundaries was established during a virtual meeting. After guideline development, a decrease in IOV was observed. The maximum volume ratio decreased from 4.7 to 3.1 and volume coefficient of variation reduced from 40% to 34%. The mean Dice similarity coefficient rose from 0.72 to 0.75 and the mean distance to agreement decreased from 3.63 to 2.95 mm.

CONCLUSIONS: Interobserver variability in prostate bed contouring exists among international genitourinary experts, although this is lower than previously reported. Consensus guidelines for MRI-based prostate bed contouring have been developed, and this has resulted in an improvement in contouring concordance. However, IOV persists and strategies such as an education program, development of a contouring atlas, and further refinement of the guidelines may lead to additional improvements.

Author List

Sritharan K, Akhiat H, Cahill D, Choi S, Choudhury A, Chung P, Diaz J, Dysager L, Hall W, Huddart R, Kerkmeijer LGW, Lawton C, Mohajer J, Murray J, Nyborg CJ, Pos FJ, Rigo M, Schytte T, Sidhom M, Sohaib A, Tan A, van der Voort van Zyp J, Vesprini D, Zelefsky MJ, Tree AC

Authors

William Adrian Hall MD Chair, Professor in the Radiation Oncology department at Medical College of Wisconsin
Colleen A. Lawton MD Emeritus Professor in the Radiation Oncology department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Humans
Magnetic Resonance Imaging
Magnetic Resonance Spectroscopy
Male
Observer Variation
Prostate
Radiotherapy Planning, Computer-Assisted
Radiotherapy, Image-Guided