Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 2013 Apr 23;127(16):1702-11
Date
03/30/2013Pubmed ID
23538380DOI
10.1161/CIRCULATIONAHA.112.000685Scopus ID
2-s2.0-84876584927 (requires institutional sign-in at Scopus site) 456 CitationsAbstract
BACKGROUND: Recent data suggest that the Berlin Heart EXCOR Pediatric ventricular assist device is superior to extracorporeal membrane oxygenation for bridge to heart transplantation. Published data are limited to 1 in 4 children who received the device as part of the US clinical trial. We analyzed outcomes for all US children who received the EXCOR to characterize device outcomes in an unselected cohort and to identify risk factors for mortality to facilitate patient selection.
METHODS AND RESULTS: This multicenter, prospective cohort study involved all children implanted with the Berlin Heart EXCOR Pediatric ventricular assist device at 47 centers from May 2007 through December 2010. Multiphase nonproportional hazards modeling was used to identify risk factors for early (<2 months) and late mortality. Of 204 children supported with the EXCOR, the median duration of support was 40 days (range, 1-435 days). Survival at 12 months was 75%, including 64% who reached transplantation, 6% who recovered, and 5% who were alive on the device. Multivariable analysis identified lower weight, biventricular assist device support, and elevated bilirubin as risk factors for early mortality and bilirubin extremes and renal dysfunction as risk factors for late mortality. Neurological dysfunction occurred in 29% and was the leading cause of death.
CONCLUSIONS: Use of the Berlin Heart EXCOR has risen dramatically over the past decade. The EXCOR has emerged as a new treatment standard in the United States for pediatric bridge to transplantation. Three-quarters of children survived to transplantation or recovery; an important fraction experienced neurological dysfunction. Smaller patient size, renal dysfunction, hepatic dysfunction, and biventricular assist device use were associated with mortality, whereas extracorporeal membrane oxygenation before implantation and congenital heart disease were not.
Author List
Almond CS, Morales DL, Blackstone EH, Turrentine MW, Imamura M, Massicotte MP, Jordan LC, Devaney EJ, Ravishankar C, Kanter KR, Holman W, Kroslowitz R, Tjossem C, Thuita L, Cohen GA, Buchholz H, St Louis JD, Nguyen K, Niebler RA, Walters HL 3rd, Reemtsen B, Wearden PD, Reinhartz O, Guleserian KJ, Mitchell MB, Bleiweis MS, Canter CE, Humpl TAuthor
Robert Niebler MD Professor in the Pediatrics department at Medical College of WisconsinMESH terms used to index this publication - Major topics in bold
Body SizeCause of Death
Child
Child, Preschool
Comorbidity
Compassionate Use Trials
Equipment Design
Extracorporeal Membrane Oxygenation
Female
Heart Defects, Congenital
Heart Diseases
Heart Transplantation
Heart-Assist Devices
Hemorrhage
Humans
Hyperbilirubinemia
Infant
Kidney Diseases
Liver Diseases
Male
Mortality
Multiple Organ Failure
Proportional Hazards Models
Risk
Stroke
Survival Rate
Treatment Outcome
Waiting Lists









