Galvanic corrosion between various combinations of orthodontic brackets and archwires. Am J Orthod Dentofacial Orthop 2011 Jul;140(1):25-31
Date
07/05/2011Pubmed ID
21724083DOI
10.1016/j.ajodo.2010.05.021Scopus ID
2-s2.0-79959922941 (requires institutional sign-in at Scopus site) 29 CitationsAbstract
INTRODUCTION: The purpose of this study was to compare galvanic currents generated by different combinations of commonly used brackets and archwires.
METHODS: As-received stainless steel, nickel-titanium, and beta-titanium wires were coupled to stainless steel and titanium brackets in an artificial saliva medium. The galvanic current and amount of charge transferred for each pair were monitored with a zero resistance ammeter for 10 hours.
RESULTS: Two-way analysis of variance (ANOVA) showed a significant difference in charge and galvanic currents when factored for type of bracket (P <0.001), but no significant difference between them when factored by type of wire (P >0.05). Specifically, a brazed stainless steel bracket was significantly greater in charge transferred and 10-hour galvanic current than metal injection molded stainless steel and titanium brackets (P <0.001), which were not different from each other (P >0.05).
CONCLUSIONS: The method of bracket manufacturing might be of equal or more relevance to galvanic corrosion susceptibility than bracket composition.
Author List
Bakhtari A, Bradley TG, Lobb WK, Berzins DWAuthor
David Berzins BS,PhD Graduate Program Director for Dental Biomaterials in the General Dental Sciences/Dental Biomaterials department at Marquette UniversityMESH terms used to index this publication - Major topics in bold
Analysis of VarianceCorrosion
Dental Alloys
Electric Conductivity
Electrogalvanism, Intraoral
Materials Testing
Nickel
Orthodontic Appliance Design
Orthodontic Brackets
Orthodontic Wires
Potentiometry
Saliva, Artificial
Stainless Steel
Statistics, Nonparametric
Titanium