Medical College of Wisconsin
CTSIResearch InformaticsREDCap

The effect of water storage on the bending properties of esthetic, fiber-reinforced composite orthodontic archwires. Angle Orthod 2014 May;84(3):417-23

Date

10/31/2013

Pubmed ID

24168402

Pubmed Central ID

PMC8667494

DOI

10.2319/061213-443.1

Scopus ID

2-s2.0-84900464387 (requires institutional sign-in at Scopus site)   8 Citations

Abstract

OBJECTIVE: To study the effect of water storage on the bending properties of fiber-reinforced composite archwires and compare it to nickel-titanium (NiTi), stainless steel (SS), and beta-titanium archwires.

MATERIALS AND METHODS: Align A, B, and C and TorQ A and B composite wires from BioMers Products, 0.014-, 0.016, and 0.018-inch, and 0.019×0.025-inch NiTi, 0.016-inch SS, and 0.019×0.025-inch beta-titanium archwires were tested (n=10/type/size/condition). A 20-mm segment was cut from each end of the archwire; one end was then stored in water at 37°C for 30 days, while the other was stored dry. The segments were tested using three-point bending to a maximum deflection of 3.1 mm with force monitored during loading (activation) and unloading (deactivation). Statistical analysis was completed via two-way analysis of variance with wire and condition (dry and water-stored) as factors.

RESULTS: In terms of stiffness and force delivery during activation, in general: beta-titanium was >TorQ B>TorQ A>0.019×0.025-inch NiTi and 0.016-inch SS>Align C>0.018-inch NiTi>Align B>0.016-inch NiTi>Align A>0.014-inch NiTi. Water exposure was detrimental to the larger translucent wires (Align B and C, TorQ A and B) because they were more likely to craze during bending, resulting in decreased forces applied at a given deflection. Align A and the alloy wires were not significantly (P>.05) affected by water storage. Overall, the alloy wires possessed more consistent force values compared to the composite wires.

CONCLUSION: Environmental conditions are more likely to affect fiber-reinforced composite archwires compared to alloy wires.

Author List

Chang JH, Berzins DW, Pruszynski JE, Ballard RW

Author

David Berzins BS,PhD Graduate Program Director for Dental Biomaterials in the General Dental Sciences/Dental Biomaterials department at Marquette University




MESH terms used to index this publication - Major topics in bold

Composite Resins
Dental Alloys
Dental Materials
Dental Stress Analysis
Elasticity
Humans
Materials Testing
Nickel
Orthodontic Wires
Stainless Steel
Stress, Mechanical
Temperature
Time Factors
Titanium
Water