Finite element (FE) modeling of the mandible: from geometric model to tetrahedral volumetric mesh. Stud Health Technol Inform 2002;85:593-6
Date
10/02/2004Pubmed ID
15458158Abstract
This paper presents our experience in using FE modeling of clinically relevant cases specifically in mandibular surgery. A semi-automatic procedure integrated with a group of Virtual Basic-based codes has been developed to clean the geometric models. Consequently, the time required for generate the tetrahedral volumetric mesh of mandible from patient-specific CT data has been reduced to less than 40 hours. Pre- and post-operation FE meshes are shown to be consistent and can be used for further modeling and analysis.