Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Radiographic detection of mobilizable lung water: the gravitational shift test. AJR Am J Roentgenol 1982 Jan;138(1):59-64

Date

01/01/1982

Pubmed ID

6976713

DOI

10.2214/ajr.138.1.59

Scopus ID

2-s2.0-0020043608 (requires institutional sign-in at Scopus site)   9 Citations

Abstract

A radiographic method for detecting excessive lung water in patients with pulmonary infiltrates of uncertain cause is described. The gravitational shift test uses bedside frontal films before and after prolonged lateral decubitus positioning. Excess lung water is identified by detecting a shift in infiltrate to the dependent lung while the opposite side clears or remains stable. The test was evaluated in 33 patients with infiltrates of well defined etiology. Twelve patients had heart failure or fluid overload (edema): 14 had pulmonary infection or parenchymal damage (inflammation); and seven had inflammation plus edema. Infiltrates shifted to the dependent lung in 85% of patients with lung edema, but did not shift in 78% of patients with inflammatory disease. The test also detected excess lung water in six of seven patients with underlying inflammatory disease. Each patient with a positive test showed clinical, physiologic, and radiographic improvement after therapy directed at mobilizing excessive lung water. When the differential diagnosis of a diffuse infiltrate is in question, a positive test represents a strong indication for a trial of diuretic therapy.

Author List

Zimmerman JE, Goodman LR, St Andre AC, Wyman AC



MESH terms used to index this publication - Major topics in bold

Body Water
Diagnosis, Differential
Gravitation
Humans
Lung
Pneumonia
Posture
Pulmonary Edema
Radiography