Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Rationale and design of a randomized clinical trial to assess the safety and efficacy of cardiac resynchronization therapy in patients with advanced heart failure: the Multicenter InSync Randomized Clinical Evaluation (MIRACLE). J Card Fail 2000 Dec;6(4):369-80

Date

01/06/2001

Pubmed ID

11145762

DOI

10.1054/jcaf.2000.20841

Scopus ID

2-s2.0-0034522062 (requires institutional sign-in at Scopus site)   154 Citations

Abstract

Up to 50% of patients with chronic systolic heart failure have interventricular conduction delays, such as left bundle branch block, that result in abnormal electrical depolarization of the heart. Prolonged QRS duration results in abnormal interventricular septal wall motion, decreased contractility, reduced diastolic filling time, and prolonged duration of mitral regurgitation, which places the failing heart at a significant mechanical disadvantage. Prolonged QRS duration has been associated with poor outcome in heart failure patients. Atrial-synchronized, biventricular pacing or cardiac resynchronization therapy optimizes atrial-ventricular delay, narrows QRS duration, and seems promising in the management of advanced heart failure patients. Initial studies show improved quality of life and functional capacity compared with baseline or with no pacing. These studies, however, were either uncontrolled or poorly controlled, unblinded or only single-blinded, and enrolled small numbers of patients. The Multicenter InSync Randomized Clinical Evaluation (MIRACLE) is a large, prospective, randomized, double-blind, controlled trial designed to more definitively evaluate the clinical efficacy and safety of cardiac resynchronization for heart failure. The study is being completed in 3 phases (an initial pilot phase, a pivotal phase, and an expansion phase), enrolling 500 patients with New York Heart Association (NYHA) class III and IV systolic heart failure and QRS durations of 130 ms or more. Prospectively defined primary end points for the pivotal phase include evaluation of safety (implant success rate, freedom from stimulator- and ventricular-lead-related complications) and effects on functional status (quality of life, NYHA class, 6-minute hall walk distance) at 6 months. A variety of secondary end points will further define the efficacy and mechanism(s) of action of cardiac resynchronization in heart failure. The pivotal phase of MIRACLE will conclude in January 2001.

Author List

Abraham WT

Author

James A. Roth MD Associate Professor in the Medicine department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Activities of Daily Living
Cardiac Pacing, Artificial
Double-Blind Method
Heart Block
Heart Failure
Humans
Multicenter Studies as Topic
Patient Selection
Prospective Studies
Quality of Life
Randomized Controlled Trials as Topic
Research Design
Safety
Treatment Outcome