Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009 Dec 03;361(23):2241-51

Date

11/19/2009

Pubmed ID

19920051

DOI

10.1056/NEJMoa0909938

Scopus ID

2-s2.0-73349129701 (requires institutional sign-in at Scopus site)   2593 Citations

Abstract

BACKGROUND: Patients with advanced heart failure have improved survival rates and quality of life when treated with implanted pulsatile-flow left ventricular assist devices as compared with medical therapy. New continuous-flow devices are smaller and may be more durable than the pulsatile-flow devices.

METHODS: In this randomized trial, we enrolled patients with advanced heart failure who were ineligible for transplantation, in a 2:1 ratio, to undergo implantation of a continuous-flow device (134 patients) or the currently approved pulsatile-flow device (66 patients). The primary composite end point was, at 2 years, survival free from disabling stroke and reoperation to repair or replace the device. Secondary end points included survival, frequency of adverse events, the quality of life, and functional capacity.

RESULTS: Preoperative characteristics were similar in the two treatment groups, with a median age of 64 years (range, 26 to 81), a mean left ventricular ejection fraction of 17%, and nearly 80% of patients receiving intravenous inotropic agents. The primary composite end point was achieved in more patients with continuous-flow devices than with pulsatile-flow devices (62 of 134 [46%] vs. 7 of 66 [11%]; P<0.001; hazard ratio, 0.38; 95% confidence interval, 0.27 to 0.54; P<0.001), and patients with continuous-flow devices had superior actuarial survival rates at 2 years (58% vs. 24%, P=0.008). Adverse events and device replacements were less frequent in patients with the continuous-flow device. The quality of life and functional capacity improved significantly in both groups.

CONCLUSIONS: Treatment with a continuous-flow left ventricular assist device in patients with advanced heart failure significantly improved the probability of survival free from stroke and device failure at 2 years as compared with a pulsatile device. Both devices significantly improved the quality of life and functional capacity. (ClinicalTrials.gov number, NCT00121485.)

Author List

Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM 3rd, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, HeartMate II Investigators

Author

Takushi Kohmoto MD, PhD Professor in the Surgery department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Actuarial Analysis
Adult
Aged
Aged, 80 and over
Cause of Death
Female
Heart Failure
Heart-Assist Devices
Humans
Kaplan-Meier Estimate
Male
Middle Aged
Proportional Hazards Models
Prosthesis Design
Prosthesis Failure
Quality of Life
Stroke
Stroke Volume