Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Effects of the selective thromboxane synthetase inhibitor dazoxiben on variations in cyclic blood flow in stenosed canine coronary arteries. Circulation 1984 Jun;69(6):1161-70

Date

06/01/1984

Pubmed ID

6546902

DOI

10.1161/01.cir.69.6.1161

Abstract

Recent studies suggest that platelet activation and subsequent thromboxane (TX) A2 release play important roles in certain coronary syndromes. To further test this possibility, we examined the ability of a selective TXA2-synthetase inhibitor, dazoxiben (UK-37-248), to abolish cyclic flow reductions (CFRs) that occur in experimentally stenosed canine coronary arteries. CFRs, which are characterized by progressive declines in coronary blood flow and interrupted by sudden and usually spontaneous restorations of flow, were produced by placing hard plastic cylindrical constrictors (5 mm long X 4.5 mm outer diameter) on the proximal left anterior descending or circumflex coronary artery in open-chest, anesthetized dogs. Coronary blood flow was measured with pulsed Doppler flow probes placed proximal to the constrictors and regional myocardial blood flow with 15 micron radiolabeled microspheres. CFRs were observed for 1 hr, during which coronary blood flow was monitored continuously. Regional myocardial blood flow was measured before constriction, when coronary blood flow appeared to be at its nadir, and after spontaneous restorations of flow. After 1 hr dazoxiben (2.5 mg/kg iv) or an equal volume of saline was given and coronary blood flow was monitored for another hour. Dazoxiben abolished CFRs completely in 18 of 28 dogs and significantly reduced their frequency in the dogs receiving the drug (10.1 +/- 0.8 vs 3.2 +/- 1.0 per hour [+/- SE]; p less than .001, n = 28). The frequency and magnitude of variations in cyclic blood flow were unchanged after saline (8.8 +/- 0.8 vs 9.0 +/- 1.0 per hour; p = NS, n = 13). The lowest levels of coronary blood flow before and after dazoxiben were 8.6 +/- 2.2% and 48.8 +/- 5.4% of control, respectively (p less than .001, n = 28), whereas this parameter remained unchanged after saline (18.7 +/- 5.7% vs 13.4 +/- 4.1%, respectively; n = 13). The levels of TXB2 and 6-keto-prostaglandin (PG) F1 alpha (stable breakdown products of TXA2 and prostacyclin, respectively) were measured in blood collected from aortic and distal coronary arterial catheters before coronary constriction (control), during CFRs, and after administration of dazoxiben. TXB2 levels measured distal to the stenosis were increased fivefold during CFRs (352 +/- 126 vs 71 +/- 18 pg/ml plasma; p less than .03) and were reduced to preconstriction (control) levels by dazoxiben (57 +/- 12 pg/ml). Aortic TXB2 levels almost doubled with CFRs and also returned to control levels after dazoxiben.(ABSTRACT TRUNCATED AT 400 WORDS)

Author List

Bush LR, Campbell WB, Buja LM, Tilton GD, Willerson JT

Author

William B. Campbell PhD Professor in the Pharmacology and Toxicology department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5,13-dienoic Acid
6-Ketoprostaglandin F1 alpha
Animals
Coronary Circulation
Coronary Disease
Coronary Vessels
Dogs
Female
Hemodynamics
Imidazoles
Male
Platelet Aggregation
Prostaglandin Endoperoxides, Synthetic
Thromboxane B2