Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO-enhanced MR imaging. Radiology 2005 Oct;237(1):170-80

Date

08/30/2005

Pubmed ID

16126930

DOI

10.1148/radiol.2371041444

Scopus ID

2-s2.0-25144432834 (requires institutional sign-in at Scopus site)   134 Citations

Abstract

PURPOSE: To prospectively compare accuracy of dynamic contrast material-enhanced thin-section multi-detector row helical computed tomography (CT), high-spatial-resolution three-dimensional (3D) dynamic gadolinium-enhanced magnetic resonance (MR) imaging, and superparamagnetic iron oxide (SPIO)-enhanced MR imaging with optimized gradient-echo (GRE) sequence for depiction of hepatic lesions; surgery and histologic analysis were the reference standard.

MATERIALS AND METHODS: Local ethics committee approval was granted, and written informed consent was obtained. Fifty-eight patients (45 men, 13 women; age range, 47-82 years) with hepatic metastases were imaged with multi-detector row CT (3.2-mm section thickness), 3D dynamic gadolinium-enhanced MR imaging (2.5-mm effective section thickness), and SPIO-enhanced MR by using an optimized T2-weighted GRE sequence. Images were reviewed independently by two blinded observers who identified and localized lesions with a four-point confidence scale. Accuracy of each technique was measured with alternative free-response receiver operating characteristic analysis. Results were correlated with findings at surgery with intraoperative ultrasonography or histopathologic examination. Statistical differences among techniques for each observer were measured.

RESULTS: Accuracy values for each observer for all metastases (n = 215) and 1.0-cm or smaller metastases (n = 80), respectively, follow: For CT, those for reader 1 were 0.82 and 0.65; for reader 2, 0.81 and 0.68. For gadolinium-enhanced MR imaging, those for reader 1 were 0.92 and 0.79; for reader 2, 0.90 and 0.76. For SPIO-enhanced MR imaging, those for reader 1 were 0.92 and 0.83; for reader 2, 0.92 and 0.81. For all metastases for both observers, there was no significant difference between MR techniques, but both were significantly more accurate than CT (P < .01). For metastases 1.0 cm or smaller and one observer, there was no significant difference between MR techniques, but both were more accurate than CT (P < .01); for the other observer, SPIO-enhanced MR imaging was more accurate than gadolinium-enhanced MR imaging (P < .05) and CT (P < .02), but there was no significant difference between gadolinium-enhanced MR imaging and CT (P = .2).

CONCLUSION: Accuracy for gadolinium-enhanced MR imaging and SPIO-enhanced MR imaging was similar. Both techniques were significantly more accurate than CT.

Author List

Ward J, Robinson PJ, Guthrie JA, Downing S, Wilson D, Lodge JP, Prasad KR, Toogood GJ, Wyatt JI

Author

Kondragunta Rajendra Prasad MBBS Professor in the Surgery department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Aged
Aged, 80 and over
False Positive Reactions
Female
Gadolinium
Hepatectomy
Humans
Image Enhancement
Liver Neoplasms
Magnetic Resonance Imaging
Male
Middle Aged
Observer Variation
Prospective Studies
ROC Curve
Sensitivity and Specificity
Tomography, Spiral Computed