Effect of an inspiratory impedance threshold device on hemodynamics during conventional manual cardiopulmonary resuscitation. Resuscitation 2005 Jul;66(1):13-20

Date

07/05/2005

Pubmed ID

15993724

DOI

10.1016/j.resuscitation.2004.12.027

Scopus ID

2-s2.0-21544463161 (requires institutional sign-in at Scopus site)   79 Citations

Abstract

BACKGROUND: In animals in cardiac arrest, an inspiratory impedance threshold device (ITD) has been shown to improve hemodynamics and neurologically intact survival. The objective of this study was to determine whether an ITD would improve blood pressure (BP) in patients receiving CPR for out-of-hospital cardiac arrest.

METHODS: This prospective, randomized, double-blind, intention-to-treat study was conducted in the Milwaukee, WI, emergency medical services (EMS) system. EMS personnel used an active (functional) or sham (non-functional) ITD on a tracheal tube on adults in cardiac arrest of presumed cardiac etiology. Care between groups was similar except for ITD type. Low dose epinephrine (1mg) was used per American Heart Association Guidelines. Femoral arterial BP (mmHg) was measured invasively during CPR.

RESULTS: Mean+/-S.D. time from ITD placement to first invasive BP recording was approximately 14 min. Twelve patients were treated with a sham ITD versus 10 patients with an active ITD. Systolic BPs (mean+/-S.D.) [number of patients treated at given time point] at T = 0 (time of first arterial BP measurement), and T=2, 5 and 7 min were 85+/-29 [10], 85+/-23 [10], 85+/-16 [9] and 69+/-22 [8] in the group receiving an active ITD compared with 43+/-15 [12], 47+/-16 [12], 47+/-20 [9], and 52+/-23 [9] in subjects treated with a sham ITD, respectively (p < 0.01 for all times). Diastolic BPs at T = 0, 2, 5 and 7 min were 20+/-12, 21+/-13, 23+/-15 and 25+/-14 in the group receiving an active ITD compared with 15+/-9, 17+/-8, 17+/-9 and 19+/-8 in subjects treated with a sham ITD, respectively (p = NS for all times). No significant adverse device events were reported.

CONCLUSIONS: Use of the active ITD was found to increase systolic pressures safely and significantly in patients in cardiac arrest compared with sham controls.

Author List

Pirrallo RG, Aufderheide TP, Provo TA, Lurie KG

Author

Tom P. Aufderheide MD Professor in the Emergency Medicine department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Aged
Analysis of Variance
Cardiopulmonary Resuscitation
Double-Blind Method
Emergency Medical Services
Female
Heart Arrest
Humans
Male
Middle Aged
Positive-Pressure Respiration
Prospective Studies
Pulmonary Edema
Recovery of Function
Survival Analysis
Wisconsin