Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Opacification of the genitourinary collecting system during MDCT urography with enhanced CT digital radiography: nonsaline versus saline bolus. AJR Am J Roentgenol 2006 Jan;186(1):122-9

Date

12/17/2005

Pubmed ID

16357390

DOI

10.2214/AJR.04.1835

Scopus ID

2-s2.0-33644840043 (requires institutional sign-in at Scopus site)   43 Citations

Abstract

OBJECTIVE: The purpose of this study was to determine whether a saline bolus during CT urography improves urinary collecting system opacification and whether the addition of enhanced CT digital radiography (CTDR) improves urinary collecting system visualization with or without a saline bolus.

MATERIALS AND METHODS: One hundred eight CT urography and enhanced CTDR examinations were reviewed. Fifty-four patients were given a saline bolus during CT urography, and 54 patients underwent CT urography without a saline bolus. Urinary collecting system opacification was evaluated by group (saline vs nonsaline), imaging technique (CT urography alone vs CT urography plus enhanced CTDR), number of enhanced CTDR images, and site of nonopacified urinary segments. Using a multivariate logistic regression model, we determined significance of variables and odds of complete opacification.

RESULTS: In the saline group, 248 nonopacified sites were identified on CT urography alone and 95 sites with CT urography plus enhanced CTDR. In the nonsaline group, 185 nonopacified sites were identified on CT urography alone and 59 sites with CT urography plus enhanced CTDR. Combining both groups, 433 nonopacified sites were identified with CT urography alone and 154 sites with CT urography plus enhanced CTDR. Multivariate logistic regression showed significance for group (p = 0.010), imaging method (p < 0.0001), number of enhanced CTDR images (p = 0.048), and site of segment opacification (p < 0.0001). The renal pelvis shows the greatest odds and the distal ureter the lowest odds for complete opacification by group or imaging method.

CONCLUSION: The addition of a saline bolus offers no improvement, whereas the addition of enhanced CTDR offers significant improvement in collecting system opacification during CT urography.

Author List

Sudakoff GS, Dunn DP, Hellman RS, Laguna MA, Wilson CR, Prost RW, Eastwood DC, Lim HJ

Author

Mario A. Laguna MD Assistant Professor in the Radiology department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Adult
Aged
Aged, 80 and over
Female
Hematuria
Humans
Logistic Models
Male
Middle Aged
Sodium Chloride
Tomography, X-Ray Computed
Urography