Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves). J Am Coll Cardiol 2013 Jun 25;61(25):2514-21

Date

04/30/2013

Pubmed ID

23623915

Pubmed Central ID

PMC3931006

DOI

10.1016/j.jacc.2013.02.087

Scopus ID

2-s2.0-84879222556 (requires institutional sign-in at Scopus site)   208 Citations

Abstract

OBJECTIVES: This study sought to compare echocardiographic findings in patients with critical aortic stenosis following surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR).

BACKGROUND: The PARTNER (Placement of Aortic Transcatheter Valves) trial randomized patients 1:1 to SAVR or TAVR.

METHODS: Echocardiograms were obtained at baseline, discharge, 30 days, 6 months, 1 year, and 2 years after the procedure and analyzed in a core laboratory. For the analysis of post-implantation variables, the first interpretable study (≤6 months) was used.

RESULTS: Both groups showed a decrease in aortic valve gradients and increase in effective orifice area (EOA) (p < 0.0001), which remained stable over 2 years. Compared with SAVR, TAVR resulted in larger indexed EOA (p = 0.038), less prosthesis-patient mismatch (p = 0.019), and more total and paravalvular aortic regurgitation (p < 0.0001). Baseline echocardiographic univariate predictors of death were lower peak transaortic gradient in TAVR patients, and low left ventricular diastolic volume, low stroke volume, and greater severity of mitral regurgitation in SAVR patients. Post-implantation echocardiographic univariate predictors of death were: larger left ventricular diastolic volume, left ventricular systolic volume and EOA, decreased ejection fraction, and greater aortic regurgitation in TAVR patients; and smaller left ventricular systolic and diastolic volumes, low stroke volume, smaller EOA, and prosthesis-patient mismatch in SAVR patients.

CONCLUSIONS: Patients randomized to either SAVR or TAVR experience enduring, significant reductions in transaortic gradients and increase in EOA. Compared with SAVR, TAVR patients had higher indexed EOA, lower prosthesis-patient mismatch, and more aortic regurgitation. Univariate predictors of death for the TAVR and SAVR groups differed and might allow future refinement in patient selection. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894).

Author List

Hahn RT, Pibarot P, Stewart WJ, Weissman NJ, Gopalakrishnan D, Keane MG, Anwaruddin S, Wang Z, Bilsker M, Lindman BR, Herrmann HC, Kodali SK, Makkar R, Thourani VH, Svensson LG, Akin JJ, Anderson WN, Leon MB, Douglas PS

Author

Saif Anwaruddin MD Associate Professor in the Medicine department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Aged
Aged, 80 and over
Aortic Valve Stenosis
Cardiac Catheterization
Cohort Studies
Echocardiography
Female
Follow-Up Studies
Heart Valve Prosthesis Implantation
Humans
Longitudinal Studies
Male
Severity of Illness Index