Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative. Circulation 2018 Feb 06;137(6):589-601

Date

10/19/2017

Pubmed ID

29042354

DOI

10.1161/CIRCULATIONAHA.117.029987

Scopus ID

2-s2.0-85046953565 (requires institutional sign-in at Scopus site)   157 Citations

Abstract

BACKGROUND: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking.

METHODS: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups.

RESULTS: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P=0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P<0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52-1.23; P=0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8-91.1; P<0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2-6.7] versus 9.19 days [95% CI, 7.9-10.6]; P<0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25-0.64; P<0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2-0.77; P=0.006), and larger (152 mm2/m2 [95% CI, 132-176] versus 125 mm2/m2 [95% CI, 113-138]; P=0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8-0.89] versus 0.77 [95% CI, 0.75-0.8]; P=0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up.

CONCLUSIONS: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.

Author List

Glatz AC, Petit CJ, Goldstein BH, Kelleman MS, McCracken CE, McDonnell A, Buckey T, Mascio CE, Shashidharan S, Ligon RA, Ao J, Whiteside W, Wallen WJ, Metcalf CM, Aggarwal V, Agrawal H, Qureshi AM

Author

Christina Metcalf Mckinney MD Adjunct Instructor in the Pediatrics department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Blalock-Taussig Procedure
Cardiac Catheterization
Ductus Arteriosus, Patent
Female
Hospital Mortality
Humans
Infant
Infant Mortality
Infant, Newborn
Male
Palliative Care
Pulmonary Circulation
Retrospective Studies
Risk Factors
Stents
Time Factors
Treatment Outcome
United States