Feasibility Study of Pulsatile Left Ventricular Assist Device for Prolonged Ex Vivo Lung Perfusion. Ann Thorac Surg 2015 Jun;99(6):1961-7; discussion 1967-8
Date
04/30/2015Pubmed ID
25921254DOI
10.1016/j.athoracsur.2015.02.087Scopus ID
2-s2.0-84930931335 (requires institutional sign-in at Scopus site) 8 CitationsAbstract
BACKGROUND: Ex vivo lung perfusion (EVLP) has the potential to increase the donor pool for lung transplantation by facilitating resuscitation and extended evaluation of marginal organs. Current EVLP methodology employs continuous flow (CF) pumps that produce non-pulsatile EVLP hemodynamics. In this feasibility study, we tested the hypothesis that a pulsatile flow (PF) pump will provide better EVLP support than a CF pump through delivery of physiologic hemodynamics.
METHODS: Porcine lungs were supported in an EVLP model by centrifugal CF (n = 3) or PF (n = 4) left ventricular assist devices. Lungs were ventilated at 4 to 5 mL/kg, 0.21 fraction of inspired oxygen (FiO2), and perfused with an acellular, albumin-based solution corrected for osmolarity, acid-base balance, and carbon dioxide pressure (≤20 hours at 30°C) for a minimum of 12 hours support. Prostaglandin E1 and 30% albumin were infused continuously. Hemodynamic, respiratory, and blood gas parameters were continuously monitored and digitally recorded hourly. Parenchymal biopsies were used for quantification of wet to dry weight ratio.
RESULTS: All lungs maintained function in the EVLP circuit for a minimum of 12 hours (mean 14.7 ± 1 hours) and demonstrated minimal edema formation. The PF EVLP produced higher pulsatility as demonstrated by greater energy equivalent pressure and surplus hemodynamic energy compared with CF EVLP (p < 0.05). There were no statistically significant differences in pulmonary impedance, arterial partial pressure of oxygen/fraction of inspired oxygen, wet to dry weight ratio, and peak airway pressure between CF and PF EVLP.
CONCLUSIONS: The CF and PF EVLP systems successfully maintained lungs 12+ hours using a modified Steen perfusate (XVIVO Perfusion, Inc, Goteborg, Sweden); however, there were no statistically significant differences between CF and PF groups despite higher pulsatility, suggesting that PF may not offer immediate benefits over CF for prolonged ex vivo lung preservation.
Author List
Schumer EM, Zoeller KA, Linsky PL, Monreal G, Choi Y, Giridharan GA, Sobieski MA, Slaughter MS, van Berkel VHAuthor
Paul L. Linsky MD Assistant Professor in the Surgery department at Medical College of WisconsinMESH terms used to index this publication - Major topics in bold
AnimalsFeasibility Studies
Follow-Up Studies
Heart Ventricles
Heart-Assist Devices
Lung
Lung Transplantation
Male
Organ Preservation
Perfusion
Prosthesis Design
Pulsatile Flow
Swine
Time Factors
Tissue Donors