Medical College of Wisconsin
CTSIResearch InformaticsREDCap

Spectra Optia granulocyte apheresis collections result in higher collection efficiency of viable, functional neutrophils in a randomized, crossover, multicenter trial. Transfusion 2015 Apr;55(4):748-55

Date

11/11/2014

Pubmed ID

25382805

DOI

10.1111/trf.12907

Scopus ID

2-s2.0-84926434289 (requires institutional sign-in at Scopus site)   12 Citations

Abstract

BACKGROUND: Granulocyte transfusion from healthy donors is used in the treatment of patients with granulocyte function defects, or transient neutropenia and severe bacterial or fungal infections resistant to maximal antimicrobial treatment.

STUDY DESIGN AND METHODS: This study evaluated the performance and safety of the newly developed granulocyte collection protocol of the Spectra Optia in a prospective, multicenter, open-label, randomized, paired crossover trial compared with the COBE Spectra apheresis system in a population of 32 evaluable healthy subjects. All subjects received granulocyte-colony-stimulating factor and dexamethasone before collection.

RESULTS: Granulocyte procedures from Spectra Optia apheresis procedures had an approximately 23% higher polymorphonuclear (PMN) collection efficiency (CE) than the COBE Spectra collections (mean, 53.7% vs. 43.2%; p < 0.01), while the platelet CE (10.9% vs. 10.8%, respectively) and hematocrit (7.4% vs. 7.4%) were comparable between collections on both devices. Spectra Optia collections generated a higher total PMN yield per liter of blood processed than those produced by the COBE Spectra (with means of 8.6 × 10(10) vs. 6.8 × 10(10) , respectively). Granulocyte viability was more than 99% with both devices, and chemotaxic and bacterial killing activities of circulating versus collected granulocytes were similarly preserved. Fewer operator adjustments were required with Spectra Optia and there was no significant difference in the number or intensity of adverse events between instruments.

CONCLUSION: CE of the granulocyte collection procedure with the Spectra Optia was approximately 10 percentage points higher than with the COBE Spectra, required less operator involvement, and is safe for clinical implementation.

Author List

Cancelas JA, Padmanabhan A, Le T, Ambruso DR, Rugg N, Worsham DN, Pinkard SL, Graminske S, Buck J, Goldberg J, Bill J



MESH terms used to index this publication - Major topics in bold

Automation
Biomarkers
Cell Survival
Centrifugation
Chemotaxis, Leukocyte
Cross-Over Studies
Dexamethasone
Donor Selection
Equipment Design
Granulocyte Colony-Stimulating Factor
Humans
Leukapheresis
Leukocyte Count
Leukocyte Transfusion
Living Donors
Neutropenia
Neutrophils
Prospective Studies