Medical College of Wisconsin
CTSICores SearchResearch InformaticsREDCap

Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI. PLoS One 2018;13(2):e0190427

Date

02/02/2018

Pubmed ID

29389985

Pubmed Central ID

PMC5794066

DOI

10.1371/journal.pone.0190427

Scopus ID

2-s2.0-85041307092 (requires institutional sign-in at Scopus site)   13 Citations

Abstract

Typical simultaneous blood oxygenation-level dependent (BOLD) and arterial spin labeling (ASL) sequences acquire two echoes, one perfusion-sensitive and one BOLD-sensitive. However, for ASL, spatial resolution and brain coverage are limited due to the T1 decay of the labeled blood. This study applies a sequence combining a multiband acquisition with four echoes for simultaneous BOLD and pseudo-continuous ASL (pCASL) echo planar imaging (MBME ASL/BOLD) for block-design task-fMRI. A multiband acceleration of four was employed to increase brain coverage and reduce slice-timing effects on the ASL signal. Multi-echo independent component analysis (MEICA) was implemented to automatically denoise the BOLD signal by regressing non-BOLD components. This technique led to increased temporal signal-to-noise ratio (tSNR) and BOLD sensitivity. The MEICA technique was also modified to denoise the ASL signal by regressing artifact and BOLD signals from the first echo time-series. The MBME ASL/BOLD sequence was applied to a finger-tapping task functional MRI (fMRI) experiment. Signal characteristics and activation were evaluated using single echo BOLD, combined ME BOLD, combined ME BOLD after MEICA denoising, perfusion-weighted (PW), and perfusion-weighted after MEICA denoising time-series. The PW data was extracted using both surround subtraction and high-pass filtering followed by demodulation. In addition, the CBF/BOLD response ratio and CBF/BOLD coupling were analyzed. Results showed that the MEICA denoising procedure significantly improved the BOLD signal, leading to increased BOLD sensitivity, tSNR, and activation statistics compared to conventional single echo BOLD data. At the same time, the denoised PW data showed increased tSNR and activation statistics compared to the non-denoised PW data. CBF/BOLD coupling was also increased using the denoised ASL and BOLD data. Our preliminary data suggest that the MBME ASL/BOLD sequence can be employed to collect whole-brain task-fMRI with improved data quality for both BOLD and PW time series, thus improving the results of block-design task fMRI.

Author List

Cohen AD, Nencka AS, Wang Y

Authors

Andrew S. Nencka PhD Director, Associate Professor in the Radiology department at Medical College of Wisconsin
Yang Wang MD Professor in the Radiology department at Medical College of Wisconsin




MESH terms used to index this publication - Major topics in bold

Adult
Female
Humans
Magnetic Resonance Imaging
Male
Middle Aged
Task Performance and Analysis
Young Adult